CSM® 100 GPD Thin Film Composite Membrane

Model #: RE2012-100


This Standard Size Reverse Osmosis Membrane fits in a standard membrane housing like the one on the RO unit shown here.

The same standard membrane housing can accomodate RO membranes with capacities ranging between 18-100 gallons per day (GPD).

Element is interchangeable with GE Desal membranes.

Average NaCl Rejection: 98%
Permeate Flow @ 60 PSI: 100 GPD

Specifications are based on 500 mg/L NaCl solution at 60 psi net pressure (4.1 bar), 77°F (25°C), 15% recovery after 24 hours. Individual element flux may vary ± 15%.

Click here to view a chart that shows which inorganic compounds can be removed from drinking water with this reverse osmosis membrane.

If you would like to change your membrane to a capacity other than what was originally in your Reverse Osmosis System, you must change the drain flow control also. The membrane and drain flow restrictor are sized to go together. Click here to view the drain flow restrictors we have available.

A: 0.67" B: 0.47" C: 11.73" D: 1.91" E: 0.91"

Model Name Performance Dimension Testing Pressure Test Condition
Permeates Flow Rate
GPD (m3/day)
Salt Rejec-
tion %
Diam
Inch (mm)
Length
Inch (mm)
RE1812-25 25 (94) 96.0 1.8 (46) 12 (305) 60 PSI Household Standard
RE1812-35 35 (132) 96.0 1.8 (46) 12 (305) 60 PSI Household Standard
RE1812-50 45 (170) 96.0 1.8 (45) 12 (305) 60 PSI Household Standard
RE1812-60 60 (227) 96.0 1.8 (46) 12 (305) 60 PSI Household Standard
RE1812-80 80 (303) 96.0 1.8 (46) 12 (305) 60 PSI Household Standard
RE1812-100 100 (397) 96.0 2 (50) 12 (304.8) 60 PSI Household Standard
RE1812-LP 50 (189) 93.0 2.0 (50) 12 (305) 20 PSI Household LP