Average NaCl Rejection: 95%
Permeate Flow @ 65 PSI 10 GPD
Specifications are based on 500 mg/L NaCl solution at 65 psi net pressure (4.1 bar), 77°F (25°C), 15% recovery after 24 hours. Individual element flux may vary ± 15%.
Click here to view a chart that shows which inorganic compounds can be removed from drinking water with this reverse osmosis membrane.
| A: 1.80" |
B: 11.75" |
C: 10.00" |
D: 0.875" |
E: 0.678" |
|
Model # CTA-10
|
|
 |
NSF 58 Certified
|